Zum Hauptinhalt springen Zur Suche springen Zur Hauptnavigation springen
10 Mio. Produkte
Schneller Versand
Glückliche Kunden & Autoren
BESTSELLER-Produkte
Sicherer Onlineshop

Determining the Accuracy of Urine Volume Calculations made by Stationary 2D B-Mode Ultrasonography

Produktinformationen "Determining the Accuracy of Urine Volume Calculations made by Stationary 2D B-Mode Ultrasonography"

Research Paper (postgraduate) from the year 2014 in the subject Medicine - Radiology, Nuclear Medicine, grade: A, , language: English, abstract: This study was the first of its kind in that it fills the gap in the scientific data created by the absence of any investigation making a direct comparison between 2D-sonograhpic and true urine volumes. While most hospitals in the developed world now prefer to measure urine volumes with portable bladder scanners and 3D ultrasound devices, none of these technology are widely available in Bangladesh and other developing countries. Nonetheless, hundreds to thousands of ultrasound examinations involving the measurement of maximum cystometric capacity (MCC) and postvoid residue (PVR) of urinary bladder are done with 2D stationary ultrasound every day. Despite our clinical experience that these measurements are quite accurate and reliable, it was deemed essential to establish scientific evidence in its favour.This observational study was done in the Dept of Radiology & Imaging at Bangabandhu Sheikh Mujib Medical University (BSMMU), Dhaka, Bangladesh, during the period July - December 2014. 384 adult patients who came to BSMMU for ultrasound examinations were enrolled in this study and their true urine volumes were compared against that calculated using 2D B-mode ultrasound. The findings were analysed using two statistical approaches - correlation coefficient and limits of agreement. Calculation of the correlation coefficient was done so that the findings of this study could be compared with other relevant studies, most of which have used the correlation coefficient to assess the accuracy of the ultrasound equipment (3D or portable). However, Bland & Altman's limits of agreement method is the standard statistical approach to assess agreement between two methods of clinical measurement, as determined by The Statistician, The Lancet and others.Findings of this study show that bladder urine volumes measured by 2D B-mode ultrasound had high correlation (r = 0.96, 95% CI 0.955 - 0.969, P < 0.0001) and agreement (96.35%, LoA : -7.84 ± 53.05 mL) with true urine volumes. Sonographic urine volumes were accurate in both males and females, of all adult age groups and at all volume ranges including <100 mL.
Eigenschaften "Determining the Accuracy of Urine Volume Calculations made by Stationary 2D B-Mode Ultrasonography"
Format: Taschenbuch / Softcover
Thema/BIC: Medizinische Bildverarbeitung: Radiologie, Nuklearmedizin
Verlag: GRIN Verlag

0 von 0 Bewertungen

Durchschnittliche Bewertung von 0 von 5 Sternen

Bewerten Sie dieses Produkt!

Teilen Sie Ihre Erfahrungen mit anderen Kunden.


EU Gewährleistungssiegel

Die EU führt ein verpflichtendes, einheitliches EU-Label zur Information über die gesetzliche Gewährleistung ein, ergänzt durch ein Garantielabel, sofern eine freiwillige Herstellergarantie besteht.

Ziel der neuen Regelung ist es, Verbraucherrechte transparenter darzustellen und europaweit einheitliche Informationsstandards zu schaffen. Verbraucher sollen auf einen Blick erkennen können, welche gesetzlichen Mindeststandards gelten, unabhängig davon, in welchem Land oder bei welchem Händler sie einkaufen.

EU Warranty Label

The European Union is introducing a mandatory, standardized EU label to provide information about consumers’ statutory warranty rights. This will be complemented by a guarantee label where a voluntary manufacturer’s guarantee is offered.

The purpose of this new regulation is to make consumer rights more transparent and to establish consistent information standards across the European Union. Consumers should be able to see at a glance which statutory minimum protections apply, regardless of the country or retailer from which they make a purchase.